Venni Instruments VI-3510P
E-mail this product to a friend
VI-3510P vital signs monitor provides essential measurement parameters such as SpO2 and CO2, and offer high cost-performance ratio to give care teams throughout the hospital more of the information they need right at the patient’s side, such as ambulance, doctors’ office, out-patient department, and post-operative.
- Small in size with 3.5 inch fine resolution color display
- Capable of measuring SpO2, EtCO2 (End-tidal Carbon Dioxide), InsCO2 (Inspired Carbon Dioxide) and RR (Respiration Rate)
- EtCO2 and SpO2 trend graph display for the last 12, 24, or 96 hours
- Advanced SpO2 measuring technology ensures sensitive and accurate SpO2, PR and Perfusion Index (PI) measurement
- Accurate SpO2 measurement in low perfusion situation
- Audio and visual comprehensive alarm with 3 levels of alarm events
- EtCO2, InsCO2, RR, SpO2 and PR(Pulse Rate) are displayed by big, bright numerical LEDs
- CO2 waveform, SpO2 plethysmogram and system parameters are displayed on dot matrix LCD screen
- Built-in rechargeable battery
- Optional built-in thermal printer capable of printing out waveforms and text information
Specifications
General
- 3.5″ color TFT display
- Suitable for adult, pediatric and neonatal patient
- Measurement parameters: Pulse Rate/SpO2, CO2
- Audible and visual alarms with adjustable alarm ranges
- Networkable with central monitoring system
CO2
- Technology: Infrared absorption method
- Mode of Sampling: Mainstream
- Measuring parameters: Respiration Rate, EtCO2 and InsCO2
- Typical measurement range:
- EtCO2: 0~150mmHg
- InsCO2: 3~50mmHg
- Respiration Rate: 0~150bpm (Mainstream)
- CO2 Accuracy:
- 0~40mmHg ±2mmHg
- 41~70mmHg ±5% of reading
- 71~100mmHg ±8% of reading
- 101~150mmHg ±10% of reading
- CO2 Resolution: 0.1mmHg (0~69mmHg);0.25mmHg (70~150mmHg)
SpO2
- SpO2 measurement range: 35%~99%
- SpO2 measurement accuracy:
- 75% - 99% ±2%
- 50% - 74% ±3%
- Low perfusion performance: 0.4%~5%
- Pulse rate measurement range: 30bpm~250bpm
- Pulse rate measurement accuracy: ±2bpm or 2% whichever is greater
- Performance under low perfusion condition: The measurement accuracy still keeps the above specification while the blood perfusion index is as low as 0.4%. Display range of Perfusion Index: 0.2%~20%
Printer (optional)
- Type: Built-in thermal printer
- Recording speed: 25mm/s
Power Supply
- Power supply: 100~250VAC, 50/60 Hz
- Internal power supply: 12VDC (rechargeable)
- Battery specification: 12V 2.3AH (sealed lead-acid battery)
New 18 month warranty
|